Smoky Springs

940 South Enota Dr, Gainesville, GA 30501
American
License: Food Service
Last inspected: Mar 17, 2026
90
Score
Low Risk

SMOKY SPRINGS, located at 940 South Enota Dr, Gainesville, GA, has had four food service inspections. The most recent inspection on March 17, 2026, resulted in a low-risk score of 90 with two minor violations. These violations concerned food-contact surfaces needing cleaning and sanitizing, and food and non-food contact surfaces requiring proper design and cleaning.

4
Inspections
0
Critical latest
0
Major latest
2
Minor latest
Inspection History
Mar 17, 2026
Routine
2 minor violations.
90
Aug 19, 2025
Routine
1 major violation. 1 minor violation. 1 corrected on site.
86
Dec 23, 2024
Routine
1 minor violation. 1 corrected on site.
95
May 24, 2024
Routine
3 minor violations. 1 corrected on site.
86
Violations — Mar 17, 2026 Inspection
4-2B - food-contact surfaces: cleaned & sanitized
Inspector notes: Hot water sanitizing warewasher water pressure not between 15 - 25 pounds per square inch. Observed water pressure to read 30 psi on gauge during rinse cycle while the data plate states water pressure should read between 15-25 psi. The flow pressure of the fresh hot water sanitizing rinse in a warewashing machine, as measured in the water line immediately downstream or upstream from the fresh hot water sanitizing control valve, shall be within the range specified on the machine manufacturer’s data plate and may not be less than 35 kilopascals (5 pounds per square inch) or more than 200 kilopascals (30 pounds per square inch). Corrective Actions: PIC to call Ecolab to have technician come and service the dish machine. PIC stated all dishes and equipment will be washed in the dish machine...
511-6-1.05(6)(m)
15A - food and nonfood-contact surfaces cleanable, properly designed, constructed, and used
Inspector notes: Observed rinse gauge on high temperature dish machine to display inaccurate readings. PIC used single use sticker with thermocromatic color-change band to ensure proper temperature was reached. Ambient air temperature, water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use. Corrective Actions: PIC to call Ecolab to adjust rinse gauge.
511-6-1.05(6)(q)
Priority (Critical)
Priority Foundation (Major)
Core (Minor)