Beltway 8 Express
Last inspected: Dec 10, 2024
100
Score
Beltway 8 Express, located at 11002 W Sam Houston Pkwy S in Houston, TX, had its most recent inspection on 2024-12-10. This inspection resulted in a low-risk classification with a score of 100, and no violations were recorded. Across three recorded inspections, the facility has consistently maintained a low-risk status.
3
Inspections
0
Critical latest
0
Major latest
0
Minor latest
Inspection History
Dec 10, 2024
Routine
No violations found.
100
Nov 12, 2024
Routine
4 minor violations.
View 4 violations
Backflow. an air gap between the water supply inlet and the flood level rim of the plumbing fixture / equipment / or nonfood equipment not at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch). a backflow or backsiphonage prevention device installed on a water supply system shall meet american society of sanitary engineering (asse) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. a backflow prevention device shall be located so that it can be serviced and maintained. a hose shall not be attached to a faucet unless a backflow prevention device is installed.
20-21.17(c)
Floor junctures. when allowed in this subsection, the juncture between walls and floors presenting an open seam of more than one-thirty-second of an inch.
20-21.22(f)
Construction. walls, including nonsupporting partitions / wall coverings / ceilings, of walk-in refrigerating units / food preparation areas / food storage areas / food display areas / equipment-washing areas / utensil-washing areas not light-colored / smooth / nonabsorbent / easily cleanable except for ceilings over areas used only for beverage preparation and/or service. concrete or pumice blocks used for interior wall construction in these locations shall be finished and sealed to provide an easily cleanable surface except in dry storage areas.
20-21.23(b)
Utility line/duct installation. exposed utility service lines and pipes not installed in a way that does not obstruct or prevent cleaning of the walls and ceilings. utility service lines and pipes shall not be unnecessarily exposed on walls or ceilings in those areas listed in subsection (b) of this section. service lines behind counters used only for beverage preparation may be exposed on the inside counter walls if necessary for service and if kept to a minimum. if exposed in rooms or areas allowed in subsection (c) of this section, air conditioning / ventilation / heating ducts shall be of smooth rigid metal and designed with a circular cross-section.
20-21.23(f)
82
Oct 17, 2024
Routine Inspection (001)
12 minor violations.
View 12 violations
Floors. floors and floor coverings of all food preparation, food storage, utensil-washing areas, walk-in refrigerating units, dressing rooms, locker rooms, and toilet rooms shall be kept clean.
20-21.22(a)
8-304.11(k) the permit holder shall notify customers that a copy of the most recent establishment inspection report is available upon request by posting a sign or placard in a location in the food establishment that is conspicuous to customers or by another method acceptable to the regulatory authority.
20-20(c)
Materials; general. sponges. sponges used in contact with cleaned and sanitized or in-use food-contact surfaces.
20-21.10(a)(07)
Using chemicals for sanitization. when using chemicals for sanitization, a test kit or other device that accurately measures the concentration of the solution in parts per million or milligrams per liter not provided and used.
20-21.12(g)
Hand-washing sink supplies. supply of hand-cleansing liquid / powder / bar soap not available at each hand-washing sink or group of two adjacent hand-washing sinks.
20-21.19(c)
Hand-washing signage. sign / icon / poster that notifies food employees to wash their hands not provided at all hand-washing sinks used by food employees / not clearly visible to food employees.
20-21.19(g)
Hand-washing sink maintenance. hand-washing sink / soap dispenser / hand-drying device/ related fixtures not kept clean / not in good repair.
20-21.19(d)
Containers. containers stored outside the establishment / dumpsters / compactors / compactor systems / receptacles / waste handling units for refuse / recyclables / and returnables not provided with tight-fitting lids / doors / covers, not kept covered when not in actual use. in containers designed with drains, drain plugs shall be in place at all times, except during cleaning.
20-21.20(a)(03)
Attachments. light fixtures / vent covers / wall-mounted fans / similar equipment not including decorative items attached to walls and ceilings not easily cleanable / not maintained in good repair / not kept clean.
20-21.23(g)
Maintenance. walls / ceilings, including doors, windows, skylights, and similar closures, not maintained in good repair.
20-21.23(a)
Cleaning equipment storage. after use, mops not placed in a position that allows them to air-dry without soiling walls / equipment / supplies.
20-21.28(e)
Sanitation poster not conspicuously posted in area accessible to all employees / not conforming to all requirements.
20-26(c)
55