Hacienda Bella Terra Events

425 E Little York Rd, Houston, TX 77076
Other
Last inspected: Jan 7, 2025
67
Score
Medium Risk

Hacienda Bella Terra Events, located at 425 E Little York Rd in Houston, TX, underwent a moderate risk inspection on January 7, 2025. This inspection identified eight minor violations, including issues with refrigerated storage temperature monitoring, plumbing fixture installation, and the provision of chemical sanitization test kits. The facility has a history of mostly low-risk inspections.

2
Inspections
0
Critical latest
0
Major latest
8
Minor latest
Inspection History
Jan 7, 2025
Routine Inspection (001)
8 minor violations. 1 corrected on site.
67
Nov 22, 2024
Routine
No violations found.
100
Violations — Jan 7, 2025 Inspection
Refrigerated storage. refrigeration facilities. the sensor of a temperature measuring device shall be located to measure the air temperature or a simulated product temperature in the warmest part of the mechanically refrigerated unit and designed to be easily readable.
20-21.03(b)(01)
Plumbing fixture installation. plumbing fixtures, including compartment type utensil-and-food sinks, hand-washing sinks and mop or utility sinks, not installed to preclude splashes from running down mounting surfaces behind and adjacent to the fixture. acceptable installation methods include a liquid tight seal between fixture and mounting surface, insertion into a precut counter, table or cabinet with a perimeter seal or any other effective method. all materials used shall be safe, smooth, impervious and easily cleanable.
20-21.10(m)
Using chemicals for sanitization. when using chemicals for sanitization, a test kit or other device that accurately measures the concentration of the solution in parts per million or milligrams per liter not provided and used.
20-21.12(g)
Storage. cleaned and sanitized utensils and movable equipment not stored at least six inches above the floor in a clean, dry location in a way that protects them from contamination by splash, dust, and other means.
20-21.14(b)(01)
Backflow. an air gap between the water supply inlet and the flood level rim of the plumbing fixture / equipment / or nonfood equipment not at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch). a backflow or backsiphonage prevention device installed on a water supply system shall meet american society of sanitary engineering (asse) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. a backflow prevention device shall be located so that it can be serviced and maintained. a hose shall not be attached to a faucet unless a backflow prevention device is installed.
20-21.17(c)
Hand-washing sink supplies. supply of hand-cleansing liquid / powder / bar soap not available at each hand-washing sink or group of two adjacent hand-washing sinks.
20-21.19(c)
Hand-washing sink faucets. hand-washing sink not equipped to provide water at a temperature of at least 100°f (38°c) through a mixing valve or combination faucet. hand-washing sinks in facilities providing custodial care for preschool age children that are used only by the children may provide only cold running water.
20-21.19(b)
Labeling of materials. working containers used for storing poisonous / toxic materials such as cleaners and sanitizers taken from bulk supplies not clearly / individually identified with the common name of the material. (corrected on site)
20-21.27(b)
Substantial (Critical)
Serious (Major)
General (Minor)